Can one re-assign Development Class in 4.6c?

Question:
Am unable to do....development class is always display only when I'm
looking at program or object attributes....All other data elements in the block are active and I can change...just can't touch the Dev Class....My Security wizard says not caused by security setting.....Ideas?
Answer:
Hallo Indy..Most probably U R using the class in your program wich is active. Comment all the coding concern to that particular class and try to modify the class. Umm.....Hope it solves U'r problem. Best of luck..Sri
Answer:
try SE03
...Object Directory
....Change Object Directory Entries of Objects
_________________
Jack,
Wandering Over the Hills & Far Away
Answer:
Hi Indy
In SE80 right click on the program name. Choose More Functions then Change Development Class.
Cheers
Dave
Answer:
When you create a program the system asks you for a development class. Once you have set the development class it will be in display in the program attributes.
If you need to change the development class you can do it so by
1) Going to SE38,enter the program name and Program-> Reassign (in 31X )
or
2)by running RSWBO052 in SE38/SA38.
_________________
Sunny
Answer:
try with the transaction SM31 and the table TADIR

More Articles:

runtime analysis?
Question on table control?
spool output wrong?
ws_download with header line?
ABAPer's who have worked on FI plz.?
RFC call?